Printable Copy Main Index Section ( 1* ) Index Your best Solution... ©9/2005 GSA Industries (Aust.) Pty. Ltd. ABN 71 004 784 301 Section 1 1 Air Conditioner Controls 97 152 Ranco  Type C17 Thermostats For Heat Pumps or Two Stage Operation. The C17-177 Thermostat is a standard cycling control with two electrically separate switches for automatic changeover on heat pumps. This control completes two electrical circuits in response to temperature changes for either automatic change-over on heat-cool cycling or on two-stage operations. The C17-334 Thermostat is the same as the C17-177, except one switch is adjusted to cycle within the ‘cut-out’ and ‘cut-in’ events of the other (differential within a differential). Field adjustment is not generally recommended for any of the Series C17 Controls. Cross ambient sensing bulb 9.5mm x 230mm. Electrical Ratings: 240 VAC. FLA 20. LRA 78. Replacements: C17-334 replaces C17-308, 316, 503, 506 C17-177 replaces C17-140 t Switching Sequence Switch ‘A’ Terms Cut-out °C Cut-out °C Cut-in °C Cut-in °C Terms Switch ‘B’ Cat. No. 152085   C17-334 9.4 3.6 915 Varifix 2 & 1 18.3 20.3 4 & 5 21.1 17.5 152177   C17-177 16.7 2 660 16 2 & 3 19.7 17.8 4 & 5 21.7 19.7 Part No. Range °C Diff. K Cap. Length mm Shaft Length mm Ranco  Type A22 Adaptable RAC Thermostat The function of the A22-2453 Adaptable Control is to cycle an SPDT switch in response to changes of temperature. Switch is operated by the expansion and contraction of the bellows in response to temperature sensing by a cross ambient fill bulb and capillary. Range adjustments are limited to the rotation of the dial for the required temperature set point. Differential screw adjustment in the insulator block is for factory callibration use only and is NOT to be adjusted in the field. Ranco  Type C12 Thermostat The C12-5010 Cross Ambient Thermostat will perform one of two functions – Cooling Only or Heating Only. (For Heating-Cooling operation, a manual selector switch is necessary for heat pump applications since the C12 alone will not automatically perform this function). The switch is basically an SPDT snap-acting type. Normally closed contacts open on a drop in temperature. Field adjustment is not recommended on the Range and Differential screws. However, there is a dial adjustment for a wide temperature range. The bulb of the liquid filled power element is the controlling point regardless of the temperature at the bellows and capillary tubing. Ambient temperatures have an effect on the switch operation of the C12 control. A temperature of 27°C is the selected ambient point used by the factory on control calibration. A change in ambient temperatures above or below 27°C will shift the setting slightly lower or higher respectively. Electrical Rating: 240 VAC. FLA 20. LRA 80. t Bulb and Capillary Application Cat. No. Part No. Temperature °C Switch Action Differential K Cold Out Cold In    Warm In 2.2 9.5mm x 100mm Air 152150 A22-2453 SPDT 15 17.8 33.3 Fixed 990mm Cap. Conditioner Cross Ambient Electrical Rating 240 VAC 9.5mm x 230mm 152081 C12-5010 15.6 to 36.7 1.7 Fixed Close on Temp. 660mm Cap. FLA 20 Rise Liquid Filled LRA 78 Contacts Cat. No. Part No. Range °C Diff. K Bulb and Capillary